J Physiol Boston Smyposia
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Physiol Volume 546, Number 1, 279-287, January 1, 2003 DOI: 10.1113/jphysiol.2002.029215
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
546/1/279    most recent
2002.029215v2
2002.029215v1
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vérin, E.
Right arrow Articles by Sériès, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vérin, E.
Right arrow Articles by Sériès, F.
J Physiol (2003), 546.1, pp. 279-287
© Copyright 2002 D 2003 The Physiological Society
DOI: 10.1113/jphysiol.2002.029215

Effects of continuous positive airway pressure on upper airway inspiratory dynamics in awake patients with sleep-disordered breathing

E. Vérin*†‡, T. Similowski†§ and F. Sériès*†

*Centre de recherche, Hôpital Laval, Institut universitaire de cardiologie et de pneumologie de l'Université Laval, Québec, Canada, †UPRES EA 2397, Université Paris VI Pierre et Marie Curie, Paris, France, ‡Service de Physiologie, CHU de Rouen, France and §Service de Pneumologie, Groupe Hospitalier Pitié-Salpêtrière, Assistance Publique - Hôpitaux de Paris, Paris, France

Continuous positive airway pressure (CPAP) is the main treatment of the obstructive sleep apnoea syndrome (OSAS). We assessed its effects on the upper airway (UA) dynamics in response to bilateral anterior magnetic phrenic nerve stimulation (BAMPS) in 17 awake untreated OSAS patients (15 males; 52 ± 7 years) whose effective CPAP (Peff) had been determined beforehand by a conventional titration sleep study. All twitch-related inspirations were flow-limited, flow first rising to a maximum ( Imax), then decreasing to a minimum ( Imin), and then increasing again (M-shaped pattern). Up to V dotImin, the relationship between driving pressure (Pd) and flow ( ) could adequately be fitted to a polynomial regression model ( = k1Pd + k2Pd2; r2 = 0.71-0.98, P < 0.0001). At atmospheric pressure Imax was 700 ± 377 ml s-1, Imin was 458 ± 306 ml s-1, k1 was 154.5 ± 63.9 ml s-1 (cmH2O)-1, and k2 was 10.7 ± 7.3 ml s-1 (cmH2O)-1. CPAP significantly increased Imax and Imin (peak values 1007 ± 332 ml and 837 ± 264 ml s-1, respectively) as well as k1 and k2 (peak values 300.9 ± 178.2 ml s-1 (cmH2O)-1 and 55.2 ± 65.3 ml s-1 (cmH2O)-1, respectively). With increasing CPAP, k1/k2 increased up to a peak value before decreasing. We defined as Peff,stim the CPAP value corresponding to the highest k1/k2 value. Peff,stim was correlated with Peff (Peff = 7.0 ± 2.0; Peff,stim = 6.4 ± 2.6 cmH2O; r = 0.886; 95 % CI 0.696-0.960, P < 0.001). We conclude that CPAP improves UA dynamics in OSAS and that the therapeutic CPAP to apply can be predicted during wakefulness using BAMPS.






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 The Physiological Society.